You might want to know...
You might want to know...
Connecting Expertise, Creating the Future
Contact us to explore professional testing technologies and jointly develop efficient and reliable quality controlsolutions.
Packaging Bag Testing Equipment
LEAK-01
Leak Tester
LEAK-01 Leak Tester, using negative pressure method, is applicable to leak detection of packaging bags, blister packaging, bottles, cans and boxes, etc. Through leak tests, the sealing processing and seal test results may be used for reference when determining other technical parameters. The instrument also can be used to test seal performance of specimens after falling and compression tests.
Share:
Product Features
Negative pressure method, the precise pressure test system, the test accuracy is greatly improved
Embedded micro-computer chips, simplified and efficient user interface provide users with comfortable and smooth operating experience
Imported high-speed and high-precision chips guarantee the testing accuracy and efficiency
Automatic constant pressure air supplement to ensure that the test can be carried out under preset vacuum conditions
Automatic blow back and unloading function, making the end of the test process simple and smooth
Safety design such as over-voltage safety protection and power-down memory ensure the stability of the system during the test
Equipped with standard RS232 interface, which is convenient to PC connection and data transmission
Low energy consumption makes the instrument environment-friendly
Originality design
7" HD LCD, displaying test data in real time
With gradient test mode, which is convenient to find the critical value of sample leakage pressure quickly
Vacuum degree and time can be preset, input the value can enter the test mode
With a powerful data storage function, which can store up to 50,000 test records
The result is automatically determined, and the test data can be printed
Support historical data for quick viewing and printing
Standard, modularized and systematic designs can meet personalized requirements of the users
Test Principle
The specimen is submerged in the water within the vacuum chamber, and then the vacuum chamber is evacuated to form a pressure difference between the inside and outside of specimen. The seal performance can be obtained by observing whether there are steady progression of bubbles from the specimen and how the specimen expands and restores to its original shape after vacuum release.
Reference Standard
Product Parameter
|
Specifications |
LEAK-01 |
LEAK-01 |
LEAK-01 |
LEAK-01 |
|
Vacuum Degree |
0 ~ -90kPa, 675mm Hg (Standard) |
0 ~ -90kPa, 675mm Hg (Standard) |
0 ~ -90kPa, 675mm Hg (Standard) |
0 ~ -90kPa, 675mm Hg (Standard) |
|
Accuracy of Sensor |
0.5%FS |
0.5%FS |
0.5%FS |
0.5%FS |
|
Test Mode |
Normal mode / Gradient mode |
Normal mode / Gradient mode |
Normal mode / Gradient mode |
Normal mode / Gradient mode |
|
Model & Effective Size of Vacuum Chamber |
Vacuum Chamber 300 φ270×210 (H) (Standard) |
Vacuum Chamber 400 φ360×585 (H) (Optional) |
Vacuum Chamber 500 φ460×330 (H) (Optional) |
Customization Available for Other Sizes of Vacuum Chamber |
|
Maintaining Capability of Vacuum Degree |
Automatic Compensation, Constant Pressure Maintaining & Vacuum Degree Setting by Range |
Automatic Compensation, Constant Pressure Maintaining & Vacuum Degree Setting by Range |
Automatic Compensation, Constant Pressure Maintaining & Vacuum Degree Setting by Range |
Automatic Compensation, Constant Pressure Maintaining & Vacuum Degree Setting by Range |
|
Mode of Operation Control |
Automatic Control & Touch Screen Operation |
Automatic Control & Touch Screen Operation |
Automatic Control & Touch Screen Operation |
Automatic Control & Touch Screen Operation |
|
Gas Supply Pressure |
0.7~0.9MPa (Not in supply scope) |
0.7~0.9MPa (Not in supply scope) |
0.7~0.9MPa (Not in supply scope) |
0.7~0.9MPa (Not in supply scope) |
|
Port of Gas Supply |
Φ6 mm PU Tubing |
Φ6 mm PU Tubing |
Φ6 mm PU Tubing |
Φ6 mm PU Tubing |
|
Power Supply |
AC 220V 50Hz/120V 60Hz |
AC 220V 50Hz/120V 60Hz |
AC 220V 50Hz/120V 60Hz |
AC 220V 50Hz/120V 60Hz |
|
Instrument Dimension |
Instrument: 300mm(L)×385mm(W)×150mm(H) Standard Vacuum Chamber 300: φ310×355 (H) |
Instrument: 300mm(L)×385mm(W)×150mm(H) Standard Vacuum Chamber 300: φ310×355 (H) |
Instrument: 300mm(L)×385mm(W)×150mm(H) Standard Vacuum Chamber 300: φ310×355 (H) |
Instrument: 300mm(L)×385mm(W)×150mm(H) Standard Vacuum Chamber 300: φ310×355 (H) |
|
Language |
English (standard), Russian (optional), others can be customized |
English (standard), Russian (optional), others can be customized |
English (standard), Russian (optional), others can be customized |
English (standard), Russian (optional), others can be customized |
|
Net Weight |
Instrument: 7kg, Vacuum Chamber 300: 9.5kg |
Instrument: 7kg, Vacuum Chamber 300: 9.5kg |
Instrument: 7kg, Vacuum Chamber 300: 9.5kg |
Instrument: 7kg, Vacuum Chamber 300: 9.5kg |
Applications
|
Basic Applications |
Glass Bottles, Pipes, Cans and Boxes |
|
Basic Applications |
Plastic Bottles, Pipes, Cans and Boxes |
|
Basic Applications |
Metal Bottles, Pipes, Cans and Boxes |
|
Basic Applications |
Paper Plastic Composite Bags, blister packaging and Boxes |
|
Extended Applications |
Pen Refills |
|
Extended Applications |
Electronic Components |
|
Extended Applications |
Medical Instruments |
Configuration
Standard Configuration:Instrument, Vacuum chamber
Note: 1.The air supply port of the instrument is Φ6 mm PU Tubing;
2.Customers will need to prepare for air supply.
Need support or have technical questions?
Pubtester’s testing instruments and packaging testing services help you lift efficiency and guarantee product quality. Tap the button to reach our experts and submit your inquiry today.